Use & Starting the CEL5
Updated over a week ago

WARNING: This model is intended for recreational & portable use only. This model CANNOT be permanently mounted or plumbed in any way. Doing so will void your warranty.

  1. Turn on incoming water supply. Ensure that you have adequate water pressure of between 40-50 PSI / 2.7 - 3.4 bar.

  2. Turn your water output device to its "off" position.

  3. Turn the gas valve on the cylinder all the way open.

  4. IF THE SMELL OF GAS IS DETECTED, TURN OFF THE GAS VALVE IMMEDIATELY!

  5. Set the water regulator knob on the face of the portable tankless water heater to its highest setting.

  6. Set the gas regulator knob on the face of the portable tankless water heater to its minimum setting.

  7. Turn on your water output device to the "on" position and adjust to the desired water flow.

  8. There will be a series of audible clicks and the burner will ignite. Should the burner not ignite after 5 seconds, shut off and go to the "Trouble Shooting" section of the manual.

  9. Upon completion of use or storage, open the drain valve (ribbed cylindrical stem next to the water input valve) to ensure draining of water.

  10. Turn off your gas supply.

  11. WARNING: If the outside temperature is around or below freezing (32 degrees F, 0 degrees C), ensure that the drain valve is opened and water drained from the portable tankless water heater after each use to avoid internal damage to the water regulator. You will also need to unhook the outgoing waterline to ensure that any water in the heat exchanger is drained. Failure to properly drain your portable tankless water heater will cause water damage which may or may not be reparable. Please check the warranty information found on our website.

CEL5-PS-1.jpg
Did this answer your question?